Professional Calculation Tool
VOLUME CONVERSIONStandard
Quickly convert actual intake air flow (FAD) to standard reference (Nm³ DIN 1343 & Sm³ ISO 2533).
View calculation basisNm³ (DIN 1343)
0 °C, 1.013 bar, 0% RH
Sm³ (ISO 2533)
15 °C, 1.013 bar, 0% RH
High accuracy
Magnus-Tetens Formula
INPUT PARAMETERS
Intake conditions1. Actual flow
m³
2. Air environment
°C
%
3. Pressure conditions
kPa
Pressure automatically changes with altitude. You can edit directly.
CONVERTED VOLUME
Dry Air (RH = 0%)Water partial pressure
Subtract this part to get dry air pressure
3,37 kPa
DIN 1343
T = 0 °C (273.15 K), P = 101.325 kPa
Nm³
85,69
Standard volume (Nm³)
110,73
Mass (kg)
ISO 2533
T = 15 °C (288.15 K), P = 101.325 kPa
Sm³
90,4
Standard volume (Sm³)
110,74
Mass (kg)
Configuration note:
This is a conversion calculation tool based on the Thermodynamics theory of air compressors. The volume results Nm³ and Sm³ always refer to a 0% humidity factor (Completely dry air). The mass (kg) between DIN and ISO is approximately equal due to mass conservation.
* Actual results may vary depending on operating conditions, load levels, air leakage, and system pressure.